|
Toni Mancini, Federico Mari, Annalisa Massini, Igor Melatti, and Enrico Tronci. "Simulator Semantics for System Level Formal Verification." In Proceedings Sixth International Symposium on Games, Automata, Logics and Formal Verification (GandALF 2015),., 2015. DOI: 10.4204/EPTCS.193.7.
|
|
|
V. Alimguzhin, F. Mari, I. Melatti, E. Tronci, E. Ebeid, S. A. Mikkelsen, R. H. Jacobsen, J. K. Gruber, B. Hayes, F. Huerta et al. "A Glimpse of SmartHG Project Test-bed and Communication Infrastructure." In Digital System Design (DSD), 2015 Euromicro Conference on, 225–232., 2015. DOI: 10.1109/DSD.2015.106.
Keywords: Batteries; Control systems; Databases; Production; Sensors; Servers; Smart grids; Grid State Estimation; Peak Shaving; Policy Robustness Verification; Price Policy Synthesis
|
|
|
T. Mancini, F. Mari, A. Massini, I. Melatti, and E. Tronci. "Anytime system level verification via parallel random exhaustive hardware in the loop simulation." Microprocessors and Microsystems 41 (2016): 12–28. ISSN: 0141-9331. DOI: 10.1016/j.micpro.2015.10.010.
Abstract: Abstract System level verification of cyber-physical systems has the goal of verifying that the whole (i.e., software + hardware) system meets the given specifications. Model checkers for hybrid systems cannot handle system level verification of actual systems. Thus, Hardware In the Loop Simulation (HILS) is currently the main workhorse for system level verification. By using model checking driven exhaustive HILS, System Level Formal Verification (SLFV) can be effectively carried out for actual systems. We present a parallel random exhaustive HILS based model checker for hybrid systems that, by simulating all operational scenarios exactly once in a uniform random order, is able to provide, at any time during the verification process, an upper bound to the probability that the System Under Verification exhibits an error in a yet-to-be-simulated scenario (Omission Probability). We show effectiveness of the proposed approach by presenting experimental results on SLFV of the Inverted Pendulum on a Cart and the Fuel Control System examples in the Simulink distribution. To the best of our knowledge, no previously published model checker can exhaustively verify hybrid systems of such a size and provide at any time an upper bound to the Omission Probability.
Keywords: Model Checking of Hybrid Systems; Model checking driven simulation; Hardware in the loop simulation
|
|
|
T. Mancini, F. Mari, I. Melatti, I. Salvo, and E. Tronci. "An Efficient Algorithm for Network Vulnerability Analysis Under Malicious Attacks." In Foundations of Intelligent Systems – 24th International Symposium, ISMIS 2018, Limassol, Cyprus, October 29-31, 2018, Proceedings, 302–312., 2018. Notes: Best Paper. DOI: 10.1007/978-3-030-01851-1_29.
|
|
|
T. Mancini, F. Mari, A. Massini, I. Melatti, I. Salvo, and E. Tronci. "On minimising the maximum expected verification time." Information Processing Letters (2017). DOI: 10.1016/j.ipl.2017.02.001.
|
|
|
Federico Cavaliere, Federico Mari, Igor Melatti, Giovanni Minei, Ivano Salvo, Enrico Tronci, Giovanni Verzino, and Yuri Yushtein. "Model Checking Satellite Operational Procedures." In DAta Systems In Aerospace (DASIA), Org. EuroSpace, Canadian Space Agency, CNES, ESA, EUMETSAT. San Anton, Malta, EuroSpace., 2011.
Abstract: We present a model checking approach for the automatic verification of satellite operational procedures (OPs). Building a model for a complex system as a satellite is a hard task. We overcome this obstruction by using a suitable simulator (SIMSAT) for the satellite. Our approach aims at improving OP quality assurance by automatic exhaustive exploration of all possible simulation scenarios. Moreover, our solution decreases OP verification costs by using a model checker (CMurphi) to automatically drive the simulator. We model OPs as user-executed programs observing the simulator telemetries and sending telecommands to the simulator. In order to assess feasibility of our approach we present experimental results on a simple meaningful scenario. Our results show that we can save up to 90% of verification time.
|
|
|
I. Melatti, F. Mari, T. Mancini, M. Prodanovic, and E. Tronci. "A Two-Layer Near-Optimal Strategy for Substation Constraint Management via Home Batteries." IEEE Transactions on Industrial Electronics (2021): 1. Notes: To appear. DOI: 10.1109/TIE.2021.3102431.
Abstract: Within electrical distribution networks, substation constraints management requires that aggregated power demand from residential users is kept within suitable bounds. Efficiency of substation constraints management can be measured as the reduction of constraints violations w.r.t. unmanaged demand. Home batteries hold the promise of enabling efficient and user-oblivious substation constraints management. Centralized control of home batteries would achieve optimal efficiency. However, it is hardly acceptable by users, since service providers (e.g., utilities or aggregators) would directly control batteries at user premises. Unfortunately, devising efficient hierarchical control strategies, thus overcoming the above problem, is far from easy. We present a novel two-layer control strategy for home batteries that avoids direct control of home devices by the service provider and at the same time yields near-optimal substation constraints management efficiency. Our simulation results on field data from 62 households in Denmark show that the substation constraints management efficiency achieved with our approach is at least 82% of the one obtained with a theoretical optimal centralized strategy.
|
|
|
T. Mancini, F. Mari, A. Massini, I. Melatti, and E. Tronci. "On Checking Equivalence of Simulation Scripts." Journal of Logical and Algebraic Methods in Programming (2021): 100640. ISSN: 2352-2208. DOI: 10.1016/j.jlamp.2021.100640.
Abstract: To support Model Based Design of Cyber-Physical Systems (CPSs) many simulation based approaches to System Level Formal Verification (SLFV) have been devised. Basically, these are Bounded Model Checking approaches (since simulation horizon is of course bounded) relying on simulators to compute the system dynamics and thereby verify the given system properties. The main obstacle to simulation based SLFV is the large number of simulation scenarios to be considered and thus the huge amount of simulation time needed to complete the verification task. To save on computation time, simulation based SLFV approaches exploit the capability of simulators to save and restore simulation states. Essentially, such a time saving is obtained by optimising the simulation script defining the simulation activity needed to carry out the verification task. Although such approaches aim to (bounded) formal verification, as a matter of fact, the proof of correctness of the methods to optimise simulation scripts basically relies on an intuitive semantics for simulation scripting languages. This hampers the possibility of formally showing that the optimisations introduced to speed up the simulation activity do not actually omit checking of relevant behaviours for the system under verification. The aim of this paper is to fill the above gap by presenting an operational semantics for simulation scripting languages and by proving soundness and completeness properties for it. This, in turn, enables formal proofs of equivalence between unoptimised and optimised simulation scripts.
Keywords: Formal verification, Simulation based formal verification, Formal Verification of cyber-physical systems, System-level formal verification
|
|
|
Andrea Bobbio, Ester Ciancamerla, Saverio Di Blasi, Alessandro Iacomini, Federico Mari, Igor Melatti, Michele Minichino, Alessandro Scarlatti, Enrico Tronci, Roberta Terruggia et al. "Risk analysis via heterogeneous models of SCADA interconnecting Power Grids and Telco networks." In Proceedings of Fourth International Conference on Risks and Security of Internet and Systems (CRiSIS), 90–97., 2009. DOI: 10.1109/CRISIS.2009.5411974.
Abstract: The automation of power grids by means of supervisory control and data acquisition (SCADA) systems has led to an improvement of power grid operations and functionalities but also to pervasive cyber interdependencies between power grids and telecommunication networks. Many power grid services are increasingly depending upon the adequate functionality of SCADA system which in turn strictly depends on the adequate functionality of its communication infrastructure. We propose to tackle the SCADA risk analysis by means of different and heterogeneous modeling techniques and software tools. We demonstrate the applicability of our approach through a case study on an actual SCADA system for an electrical power distribution grid. The modeling techniques we discuss aim at providing a probabilistic dependability analysis, followed by a worst case analysis in presence of malicious attacks and a real-time performance evaluation.
|
|
|
T. Mancini, F. Mari, A. Massini, I. Melatti, I. Salvo, S. Sinisi, E. Tronci, R. Ehrig, S. Röblitz, and B. Leeners. "Computing Personalised Treatments through In Silico Clinical Trials. A Case Study on Downregulation in Assisted Reproduction." In 25th RCRA International Workshop on “Experimental Evaluation of Algorithms for Solving Problems with Combinatorial Explosion” (RCRA 2018)., 2018. DOI: 10.29007/g864.
|
|